SecurityThe Security Installer’s Guide To Fishing Nots

The Security Installer’s Guide To Fishing Nots

The Security Installer’s Guide To Fishing Nots - When you’re moving wires around in sub-floors, ceilings and walls there’s no tool so vital as your fish tape, yet wire fishing takes subtlety and skill.

-

- Advertisment -
  • AcuSeek
  • HID AMICO

The Security Installer’s Guide To Fishing Nots.

The Security Installer’s Guide To Fishing Nots – When you’re moving wires around in sub-floors, ceilings and walls there’s no tool so vital as your fish tape, yet wire fishing takes subtlety and skill.

Too often a regulation cable pull turns into a nightmare because the correct procedures are not followed right from the beginning. You can’t simply twist a wire around a fishtape wireway and expect good things to happen. At the moment of greatest friction the wrap will fall apart, and this is nearly always the result of poor wraps, improper wire pulling methods, or a failure to understand the challenges of the route.

There’s no point pretending that after a complex wire pull there’s not a big temptation to apply brute force to a final snag instead of laboriously pulling out a fibre optic camera and going through the process of trying to assess exactly what’s going on with the run.

There are a number of things you need to get right from the get-go. First, don’t just mash the fishtape through the wireway. Doing so puts kinks in the tape and makes it difficult to pull the wire and this increased friction means greater chance of pull failure. Second, put some wire lubrication on the first few inches of the tape. This will help it slide over the edges of fittings and around inevitable corners.

SECTECH NZ - NEW ZEALAND AUCKLAND

There are 3 important rules in wire pulling. For a start you want to make sure your wiring does not exceed the wireway fill specified by the NEC. You also want to use the correct wireway cutting, deburring, and assembly techniques. This will eliminate many of the obstructions that make pulls hard to complete. And you must also be sure to pull the wires only after you complete the wireway. This will save you time and prevent damage to the wiring.

A common mistake is to wrap all the conductors into the fishtape hook. This makes one big knot that will likely come apart; or even get stuck so you can’t move it either direction. Remember to fasten one conductor around the fishtape hook. Don’t tape the joints individually. Tape over the open end of the fishtape hook, then tape the whole assembly.

The Security Installer’s Guide To Fishing Nots

With one person pushing and another pulling, you should be able to pull the wires through. The person who is pushing should smear lubricant on the wires as they enter the wireway, until the run is well underway. You may need to use needle nose pliers to get the end of the fishtape out.

These techniques ensure an easy pull for most sizes of wire. Unless you are pulling extremely large conductors, you shouldn’t need to use anything other than elbow grease or a good fishtape puller to complete the pull. Sometimes things don’t work out with a wire pull. There will be one corner too many, or some invisible snag. If you can’t get the fishtape through, even though you have been very careful with all aspects of the pull there are 3 options available.

SECTECH NZ - NEW ZEALAND AUCKLAND

Firstly, and often successfully on shorter wire pulls, you pull the tape back out and cover the hook with phasing tape; then coat the phasing tape with lubricant. But what if after a tough pull you’re almost there and don’t want to pull the tape all the way back out? In this case you can run a second tape in from the other end and manipulate it to connect with the first tape.

A third option is to make some loops of stiff wire and tape them in place. Then, let the first tape grab on to one of these. Now, attach the wire to the fishtape. For the best chance of pulling it through you should strip 15cm of insulation off each conductor and fasten one conductor to another, by tightly wrapping the first conductor around the second.

You can read more details on the wireway fill specified by the NEC here and read more SEN news here.

“A common mistake is to wrap all the conductors into the fishtape hook.”

- Advertisement -
John Adams
John Adamshttps://sen.news
A professional writer and editor who has been covering the security industry since 1991, John is passionate about clever applications of technology and the fusion of sensing and networking. A capable photographer John enjoys undertaking practical reviews of the latest electronic security systems.

Latest news

SecTech NZ Opens At Eden Park June 9

SecTech NZ Opens At Eden Park June 9 - See The Latest Security Tech From 26 Companies!SecTech NZ Opens...

Crown Secures Keiki Learning Centre

Crown Secures Keiki Learning Centre With Akuvox, Hikvision, Tecom and Permaconn.Crown Secures Keiki Learning Centre - Crown Security is...

ICT Showcasing Unified Protege GX Platform At SecTech 2026

ICT Showcasing Unified Protege GX Platform At SecTech 2026, positioning it as a unified approach to access control, intrusion...
- Advertisement -
SYNNEX SEAGATE

Fire Camera System Sought By Green Triangle

Fire Camera System Sought By Green Triangle Fire Alliance.Fire Camera System Sought By Green Triangle - Green Triangle Fire...

Alarm Watch Showing Video Verification Integrations At SecTech

Alarm Watch Showing Video Verification Integrations At SecTech NZ.Alarm Watch Showing Video Verification Integrations At SecTech - Alarm Watch...

Security Sought For Lambruk Solar Farm

Security Sought For Lambruk Solar Farm In North-Western NSW.Security Sought For Lambruk Solar Farm - Venn Energy has called...

Must read

Scenes From SecTech Sydney Rosehill Gardens

Scenes From SecTech Sydney Rosehill Gardens – You’re Next...

SecTech Adelaide Opens This Thursday

SecTech Adelaide Opens This Thursday May 21 – See...

Verkada Secures FedRAMP As Cloud Security Push Sharpens

Verkada Secures FedRAMP As Cloud Security Push Sharpens In...

Honeywell, Rhombus Push Cloud Video And Access

Honeywell, Rhombus Push Cloud Video And Access Integration.Honeywell, Rhombus...
- Advertisement -
SYNNEX SEAGATE

Security Sought For Lambruk Solar Farm

Security Sought For Lambruk Solar Farm In North-Western NSW.Security Sought For Lambruk Solar Farm - Venn Energy has called...

Brisbane Security Integrator Hits Market

Brisbane Security Integrator Hits Market With Asking Price Of $A669,000.Brisbane Security Integrator Hits Market - A long-established electronic security...

End Users Want Integrated CCTV Solutions

End Users Want Integrated CCTV Solutions With AI Across Multiple Sites, According To BGW Technologies' Mark Shannon. End Users Want...

HID Amico Privacy-First Biometric Access Reader At SecTech

HID Amico Privacy-First Biometric Access Reader Solves Privacy Headaches.HID Amico Privacy-First Biometric Access Reader - HID’s Amico facial recognition...

Bendigo Health Seeks Mobile Duress

Bendigo Health Seeks Mobile Duress Solution Across Hospital Precinct.Bendigo Health Seeks Mobile Duress - Bendigo Health has gone to...

VSP Showing Latest Access CCTV At SecTech

VSP Showing Latest Access CCTV At SecTech Perth Tomorrow!VSP Showing Latest Access CCTV At SecTech – VSP is showing...
- Advertisement -

You might also likeRELATED
Recommended to you